ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5905-00-758-5812, 5905007585812
RESISTOR,FIXED,WIRE WOUND,INDUCT

Federal Supply Classification
FSC 5905 - Resistors
National Item Identification Number
NIIN 007585812
Codification Country
United States
Item Name Code
INC 37403
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5905-00-758-5812
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5905-00-758-5812


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5905-00-758-5812

National Stock Number (NSN) 5905-00-758-5812, or NIIN 007585812, (resistor,fixed,wire wound,induct) was assigned July 28, 1971 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 37403. [A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF-SUPPORTING. THE ITEM MUST HAVE INHERENT CHARACTERISTICS OF INDUCING SELF-INDUCTANCE. OPPOSITION TO CURRENT FLOW IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFESTED BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUT S SUPPRESSOR, IGNITION INTERFERENCE. SEE ALSO RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5905007585812 contains an unknown precious metal.

This NSN is associated to Schedule B 8533390080: wirewound variable resistors, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

ELECTRICAL RESISTANCE
(AAPP) 100.000 OHMS
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 25.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER
(AAQG) 275.0
BODY DIAMETER
(ABPM) 0.094 INCHES NOMINAL
BODY LENGTH
(ADAQ) 0.406 INCHES NOMINAL
INCLOSURE TYPE
(AKNA) ENCAPSULATED
POWER DISSIPATION RATING IN WATTS
(AEFB) 1.000 FREE AIR
RESISTANCE TOLERANCE IN PERCENT
(AAPQ) -0.100 TO 0.100
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
STYLE DESIGNATOR
(STYL) AXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS
(AAPE) -30.0 TO 30.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS
(AAQH) -55.0 TO 275.0
TERMINAL TYPE
(CSCF) WIRE LEAD
TEST DATA DOCUMENT
(TEST) 81349-MIL-R-26 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
UNABLE TO DECODE
(STYL) UNABLE TO DECODE
TERMINAL TYPE
(AARB) WIRE LEAD
UNABLE TO DECODE
(AAQZ) UNABLE TO DECODE
UNABLE TO DECODE
(AARB) UNABLE TO DECODE
UNABLE TO DECODE
(TEST) UNABLE TO DECODE
UNABLE TO DECODE
(AAQF) UNABLE TO DECODE
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 25.0 DEG CELSIUS
III ELECTRICAL RESISTANCE
(AAPP) 100.000 OHMS
UNABLE TO DECODE
(ABPM) UNABLE TO DECODE
RESISTANCE TOLERANCE IN PERCENT
(AAPQ) -0.100/+0.100
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS
(AAPE) -30.0/+30.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS
(AAQH) -55.0/+275.0
UNABLE TO DECODE
(AARG) UNABLE TO DECODE
UNABLE TO DECODE
(AAQH) UNABLE TO DECODE
UNABLE TO DECODE
(AAPE) UNABLE TO DECODE
UNABLE TO DECODE
(AAPP) UNABLE TO DECODE
UNABLE TO DECODE
(AAQG) UNABLE TO DECODE
INCLOSURE METHOD
(AAQZ) ENCAPSULATED
UNABLE TO DECODE
(ADAQ) UNABLE TO DECODE
UNABLE TO DECODE
(AEFB) UNABLE TO DECODE
UNABLE TO DECODE
(AAPQ) UNABLE TO DECODE
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER
(AAQF) 25.0

Manufacturer Part Numbers


Related Inventory



 
Top