ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5905-01-243-9847, 5905012439847
RESISTOR,FIXED,WIRE WOUND,INDUCT

Federal Supply Classification
FSC 5905 - Resistors
National Item Identification Number
NIIN 012439847
Codification Country
United States
Item Name Code
INC 37403
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5905-01-243-9847
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5905-01-243-9847


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5905-01-243-9847

National Stock Number (NSN) 5905-01-243-9847, or NIIN 012439847, (resistor,fixed,wire wound,induct) was assigned November 5, 1986 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is somewhat common among different platforms, belonging to 4 different weapons systems.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 37403. [A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF-SUPPORTING. THE ITEM MUST HAVE INHERENT CHARACTERISTICS OF INDUCING SELF-INDUCTANCE. OPPOSITION TO CURRENT FLOW IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFESTED BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUT S SUPPRESSOR, IGNITION INTERFERENCE. SEE ALSO RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5905012439847 does not contain precious metals.

This NSN is associated to Schedule B 8533390080: wirewound variable resistors, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

RESISTANCE TOLERANCE IN PERCENT
(AAPQ) -0.100/+0.100
UNABLE TO DECODE
(AAPQ) UNABLE TO DECODE
INCLOSURE METHOD
(AAQZ) HERMETICALLY SEALED
UNABLE TO DECODE
(AGAV) UNABLE TO DECODE
UNABLE TO DECODE
(ABPM) UNABLE TO DECODE
UNABLE TO DECODE
(ADAQ) UNABLE TO DECODE
III ELECTRICAL RESISTANCE
(AAPP) 5.110 KILOHMS
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER
(AAQF) 70.0
UNABLE TO DECODE
(AAQG) UNABLE TO DECODE
ELECTRICAL RESISTANCE
(AAPP) 5.110 KILOHMS
END ITEM IDENTIFICATION
(AGAV) E3A WORILS RE
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 70.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER
(AAQG) 125.0
BODY DIAMETER
(ABPM) 0.125 INCHES NOMINAL
BODY LENGTH
(ADAQ) 0.250 INCHES NOMINAL
INCLOSURE TYPE
(AKNA) HERMETICALLY SEALED
POWER DISSIPATION RATING IN WATTS
(AEFB) 0.125 FREE AIR
RESISTANCE TOLERANCE IN PERCENT
(AAPQ) -0.100 TO 0.100
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
STYLE DESIGNATOR
(STYL) AXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS
(AAPE) -10.0 TO 10.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS
(AAQH) -55.0 TO 125.0
TERMINAL LENGTH
(ABJT) 2.000 INCHES NOMINAL
TERMINAL TYPE
(CSCF) WIRE LEAD
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS
(AAQH) -55.0/+125.0
UNABLE TO DECODE
(AAQH) UNABLE TO DECODE
UNABLE TO DECODE
(AAQZ) UNABLE TO DECODE
UNABLE TO DECODE
(AAPE) UNABLE TO DECODE
UNABLE TO DECODE
(AARG) UNABLE TO DECODE
UNABLE TO DECODE
(ABJT) UNABLE TO DECODE
UNABLE TO DECODE
(STYL) UNABLE TO DECODE
UNABLE TO DECODE
(AEFB) UNABLE TO DECODE
UNABLE TO DECODE
(AAPP) UNABLE TO DECODE
TERMINAL TYPE
(AARB) WIRE LEAD
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS
(AAPE) -10.0/+10.0
UNABLE TO DECODE
(AARB) UNABLE TO DECODE
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 70.0 DEG CELSIUS
UNABLE TO DECODE
(AAQF) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 
Top