RESISTOR,THERMAL

Federal Supply Classification
FSC 5905 - Resistors
National Item Identification Number
NIIN 013145713
Codification Country
United States
Item Name Code
INC 00309
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5905-01-314-5713
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5905-01-314-5713


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5905-01-314-5713

National Stock Number (NSN) 5905-01-314-5713, or NIIN 013145713, (resistor,thermal) was assigned February 1, 1990 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 4 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 6 suppliers. Today, 5 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 5 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 01, 2020, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00309. [A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES:TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5905013145713 does not contain precious metals.

This NSN is associated to Schedule B 8533400080: variable resistors, including potentiometers, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

AMBIENT TEMP AT FULL RATED POWER
(AEHY) 25.0 DEG CELSIUS
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 150.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 100.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -14.5/+14.5 6TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -16.3/+16.3 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -17.8/+17.8 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 125.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 50.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -12.5/+12.5 5TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -19.3/+19.3 2ND RESISTANCE-TEMPERATURE POINT
END ITEM IDENTIFICATION
(AGAV) 5805-01-187-9399 SWITCHBOARD,TELEPHONE
AMBIENT TEMP AT FULL RATED POWER
(AEHY) 25.0 CELSIUS
BODY LENGTH
(ADAQ) 0.270 INCHES MAXIMUM
CUBIC MEASURE
(CBME) 0.704 CUBIC INCHES
INCLOSURE TYPE
(AKNA) ENCAPSULATED
OVERALL DIAMETER
(ADAV) 0.260 INCHES MAXIMUM
OVERALL LENGTH
(ABHP) 11.260 INCHES MINIMUM AND 13.260 INCHES MAXIMUM
MAXIMUM OPERATING TEMP
(AEHZ) 150.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING
(AEHX) 0.014 WATTS
MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER
(CRYY) 0.138 INCHES
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR
(AKEJ) UNC
MOUNTING THREAD QUANTITY
(CGGK) 32 PER INCH
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS
(AEJB) 0.8
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -12.5 TO 12.5 5TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -12.5 TO 12.5 4TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -14.5 TO 14.5 6TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -15.0 TO 15.0 3RD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -16.3 TO 16.3 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -17.8 TO 17.8 8TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -19.2 TO 19.2 9TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -19.3 TO 19.3 2ND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -20.1 TO 20.1 1ST RESISTANCE-TEMPERATURE POINT
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 28.5 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 294.0 OHMS 9TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 4.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 401.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 504.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 549.2 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 74.3 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 1.9 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP
(AEJE) 924.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP
(CRQJ) -10.0 TO 10.0
ZERO POWER RESISTANCE
(CQWD) 10.000 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS
(AEJC) -3.90
STYLE DESIGNATOR
(STYL) SCREW MOUNTED
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -20.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -50.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 0.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 100.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 125.0 CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 150.0 CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 50.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 75.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TERMINAL LENGTH
(ABJT) 11.000 INCHES MINIMUM AND 13.000 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY
(TTQY) 2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS
(AEJA) 75.0
THREAD LENGTH
(AASA) 0.160 INCHES MINIMUM AND 0.180 INCHES MAXIMUM
MAXIMUM OPERATING TEMP
(AEHZ) 150.0 DEG CELSIUS
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP
(CRQJ) -10.0/+10.0
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) 75.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
III ZERO POWER RESISTANCE
(CQWD) 10.000 KILOHMS
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -19.2/+19.2 9TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -20.1/+20.1 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -15.0/+15.0 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER
(AEJD) -20.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT
(AEJF) -12.5/+12.5 4TH RESISTANCE-TEMPERATURE POINT
III CUBIC MEASURE
(CBME) 0.704 CUBIC INCHES

Manufacturer Part Numbers


Related Inventory



 