NSN 5910-01-066-9826, 5910010669826
CAPACITOR,FIXED,GLASS DIELECTRIC

Federal Supply Classification
FSC 5910 - Capacitors
National Item Identification Number
NIIN 010669826
Codification Country
United States
Item Name Code
INC 00004
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5910-01-066-9826
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5910-01-066-9826


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5910-01-066-9826

National Stock Number (NSN) 5910-01-066-9826, or NIIN 010669826, (capacitor,fixed,glass dielectric) was assigned October 22, 1978 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is fairly common among different weapons systems, belonging to 23 different platforms.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 10, 2014, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00004. [A CAPACITOR, WHOSE CAPACITANCE VALUE CANNOT BE ADJUSTED OR VARIED, HAVING A GLASS (SILICAS) OR GLASS LIKE SUBSTANCE (E.G., PORCELAIN, VITREOUS ENAMEL) AS THE DIELECTRIC MATERIAL. IT MAY BE A SINGLE UNIT, OR CONSIST OF TWO OR MORE FIXED UNITS WHICH CANNOT BE SEPARATED.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5910010669826 does not contain precious metals.

This NSN is associated to Schedule B 8532290040: fixed capacitors, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

UNABLE TO DECODE
(AEBT) UNABLE TO DECODE
UNABLE TO DECODE
(CQWM) UNABLE TO DECODE
UNABLE TO DECODE
(AAQL) UNABLE TO DECODE
UNABLE TO DECODE
(AARG) UNABLE TO DECODE
UNABLE TO DECODE
(ADAU) UNABLE TO DECODE
UNABLE TO DECODE
(CRTP) UNABLE TO DECODE
UNABLE TO DECODE
(CWPK) UNABLE TO DECODE
UNABLE TO DECODE
(TEST) UNABLE TO DECODE
UNABLE TO DECODE
(TTQY) UNABLE TO DECODE
UNABLE TO DECODE
(AEBZ) UNABLE TO DECODE
NONDERATED OPERATING TEMP
(CQJJ) -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
UNABLE TO DECODE
(CRHD) UNABLE TO DECODE
UNABLE TO DECODE
(CQBQ) UNABLE TO DECODE
UNABLE TO DECODE
(CQLZ) UNABLE TO DECODE
UNABLE TO DECODE
(CWJK) UNABLE TO DECODE
BODY HEIGHT
(ADAU) 0.480 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 0.812 INCHES MAXIMUM
BODY WIDTH
(ADAT) 0.185 INCHES MAXIMUM
BODY STYLE
(AAQL) W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
CAPACITANCE VALUE PER SECTION
(CQBQ) 1400.000 PICOFARADS SINGLE SECTION
CASE MATERIAL
(CWJK) GLASS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT
(CWPM) 0.0020
INSULATION RESISTANCE AT REFERENCE TEMP
(CWPK) 100000.0 MEGOHMS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
(CQWM) 300.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP
(CQJJ) -55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATOR
(AEBZ) NO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS
(CQLZ) 0.0 SINGLE SECTION
TERMINAL LENGTH
(ABJT) 1.125 INCHES MINIMUM
TERMINAL DIAMETER
(AEBT) 0.032 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY
(TTQY) 2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT
(TEST) 26055-821-002-000 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS
(CRHD) -25.0 TO 25.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION
(CRTP) -1.00 TO 1.00 PERCENT SINGLE SECTION
UNABLE TO DECODE
(ADAQ) UNABLE TO DECODE
UNABLE TO DECODE
(ADAT) UNABLE TO DECODE
III TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS
(CQLZ) 0.0 SINGLE SECTION
UNABLE TO DECODE
(CWPM) UNABLE TO DECODE
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS
(CRHD) -25.0/+25.0 SINGLE SECTION
UNABLE TO DECODE
(ABJT) UNABLE TO DECODE
TOLERANCE RANGE PER SECTION
(CRTP) -1.00/+1.00 PERCENT SINGLE SECTION
UNABLE TO DECODE
(CQJJ) UNABLE TO DECODE AND UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 
Top