ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5910-01-096-0475, 5910010960475
CAPACITOR,FIXED,MICA DIELECTRIC

Federal Supply Classification
FSC 5910 - Capacitors
National Item Identification Number
NIIN 010960475
Codification Country
United States
Item Name Code
INC 00005
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: We have 1 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5910-01-096-0475
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5910-01-096-0475


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5910-01-096-0475

National Stock Number (NSN) 5910-01-096-0475, or NIIN 010960475, (capacitor,fixed,mica dielectric) was assigned June 12, 1980 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are no manufacturer part numbers associated to this NSN. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00005. [A CAPACITOR, WHOSE CAPACITANCE VALUE CANNOT BE ADJUSTED OR VARIED, HAVING NATURAL SHEET MICA OR RECONSTITUTED FLAKED MICA FORMED INTO SHEETS AS THE DIELECTRIC MATERIAL. IT MAY BE A SINGLE UNIT, OR CONSIST OF TWO OR MORE FIXED UNITS WHICH CANNOT BE SEPARATED.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5910010960475 does not contain precious metals.

This NSN is associated to Schedule B 8532290020: fixed capacitors, mica dielectric, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

UNABLE TO DECODE
(ADAQ) UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(CQBQ) UNABLE TO DECODE
UNABLE TO DECODE
(CWPK) UNABLE TO DECODE
UNABLE TO DECODE
(AEBZ) UNABLE TO DECODE
UNABLE TO DECODE
(TEST) UNABLE TO DECODE
UNABLE TO DECODE
(CQJJ) UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(ABJT) UNABLE TO DECODE
UNABLE TO DECODE
(CQWM) UNABLE TO DECODE
TOLERANCE RANGE PER SECTION
(CRTP) -5.00/+5.00 PERCENT SINGLE SECTION
UNABLE TO DECODE
(AAQL) UNABLE TO DECODE
UNABLE TO DECODE
(AARG) UNABLE TO DECODE
UNABLE TO DECODE
(CRTP) UNABLE TO DECODE
UNABLE TO DECODE
(AARH) UNABLE TO DECODE
UNABLE TO DECODE
(ADAT) UNABLE TO DECODE
BODY HEIGHT
(ADAU) 0.090 INCHES MINIMUM AND 0.170 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 0.400 INCHES MINIMUM AND 0.450 INCHES MAXIMUM
BODY WIDTH
(ADAT) 0.360 INCHES NOMINAL
BODY STYLE
(AAQL) W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
CAPACITANCE VALUE PER SECTION
(CQBQ) 51.000 PICOFARADS SINGLE SECTION
CASE MATERIAL
(CWJK) PLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 0.225 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT
(CWPM) 0.0020
INSULATION RESISTANCE AT REFERENCE TEMP
(CWPK) 100000.0 MEGOHMS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
(CQWM) 500.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP
(CQJJ) -55.0 CELSIUS MINIMUM AND 150.0 CELSIUS MAXIMUM
RELIABILITY INDICATOR
(AARG) ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT
(AARH) 1.0000
SCHEMATIC DIAGRAM DESIGNATOR
(AEBZ) NO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS
(CRDN) -20.0 TO 100.0 SINGLE SECTION
TERMINAL LENGTH
(ABJT) 1.000 INCHES MINIMUM
TERMINAL DIAMETER
(AEBT) 0.025 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY
(TTQY) 2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT
(TEST) 81349-MIL-C-39001/5 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION
(CRTP) -5.00 TO 5.00 PERCENT SINGLE SECTION
UNABLE TO DECODE
(ADAU) UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(AEBT) UNABLE TO DECODE
UNABLE TO DECODE
(TTQY) UNABLE TO DECODE
UNABLE TO DECODE
(AEBP) UNABLE TO DECODE
UNABLE TO DECODE
(CWPM) UNABLE TO DECODE
UNABLE TO DECODE
(CWJK) UNABLE TO DECODE
NONDERATED OPERATING TEMP
(CQJJ) -55.0 DEG CELSIUS MINIMUM AND 150.0 DEG CELSIUS MAXIMUM
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS
(CRDN) -20.0/+100.0 SINGLE SECTION
UNABLE TO DECODE
(CRDN) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 
Top