ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5930-00-615-3271, 5930006153271
SWITCH,THERMOSTATIC

Federal Supply Classification
FSC 5930 - Switches
National Item Identification Number
NIIN 006153271
Codification Country
United States
Item Name Code
INC 00451
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5930-00-615-3271
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5930-00-615-3271


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5930-00-615-3271

National Stock Number (NSN) 5930-00-615-3271, or NIIN 006153271, (switch,thermostatic) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00451. [A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES:CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5930006153271 does not contain precious metals.

This NSN is associated to Schedule B 9032100000: thermostats. The Schedule B End Use is listed as measuring, testing, control instruments. NAICS classification category 334512: automatic environmental control manufacturing for residential, commercial, and appliance use.

This information was last updated on .


Technical Characteristics

III OVERALL LENGTH
(ABHP) 5.000 INCHES NOMINAL
CONTACT ADJUSTMENT RANGE
(CTYM) +0.00/+60.00 ACTUATION POINT DEGREES FAHRENHEIT
SPECIAL FEATURES
(FEAT) PMOUNTING DIMENSIONS,THREE 0.281 IN. DIAMETER MOUNTING HOLES,TWO HOLES ON TOP SPACED 2.406 IN. C TO C,ONE HOLE ON BOTTOM 0.547IN. TO THE LEFT OF VERTICAL CENTERLINE,3.281 IN. VERTICAL DISTANCEBETWEEN MOUNTING CENTERS
BODY LENGTH
(ADAQ) 4.782 INCHES NOMINAL
BULB LENGTH
(AEVU) 3.000 INCHES NOMINAL
BULB DIAMETER
(AEVV) 0.375 INCHES NOMINAL
CAPILLARY TUBE LENGTH
(AEVT) 120.000 INCHES NOMINAL
CONTACT ADJUSTMENT TYPE
(CTYS) EXTERNAL ACTUATION POINT SCREW
CONTACT ACTION STIMULUS
(CQGB) INCREASE
CONTACT ADJUSTABILITY
(CTYC) DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE
(CTYM) +0.00 TO 60.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT LOAD CURRENT RATING
(CTHF) 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
CONTACT LOAD CURRENT RATING
(CTHF) 2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 550.0 AC AT SEA LEVEL FIRST VOLTAGE
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 550.0 DC AT SEA LEVEL SECOND VOLTAGE
FREQUENCY IN HERTZ
(FREQ) 60.0 SINGLE VOLTAGE
OVERALL HEIGHT
(ABKW) 5.906 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 5.000 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 2.688 INCHES NOMINAL
MOUNTING METHOD
(AXGY) BRACKET
NONPILE-UP CONTACT ARRANGEMENT
(CRLD) 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
SPECIAL FEATURES
(FEAT) MOUNTING DIMENSIONS,THREE 0.281 IN. DIAMETER MOUNTING HOLES,TWO HOLES ON TOP SPACED 2.406 IN. C TO C,ONE HOLE ON BOTTOM 0.547IN. TO THE LEFT OF VERTICAL CENTERLINE,3.281 IN. VERTICAL DISTANCEBETWEEN MOUNTING CENTERS
TEMP SENSING ELEMENT TYPE
(AKBY) CAPILLARY TUBE-BULB
TERMINAL TYPE
(CSCF) TAB W/SCREW

Manufacturer Part Numbers


Related Inventory



 
Top