NSN 5950-00-243-1466, 5950002431466
Cancelled -> Replaced by 5950000043899

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 002431466
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: We have 1 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-243-1466
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-243-1466


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-243-1466

National Stock Number (NSN) 5950-00-243-1466, or NIIN 002431466, (transformer,power) was assigned November 2, 1970 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5950000043899.

There are 4 manufacturer part numbers associated with this NSN. 3 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950002431466 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

UNABLE TO DECODE
(AAJF) UNABLE TO DECODE
BODY HEIGHT
(ADAU) 1.938 INCHES NOMINAL
BODY LENGTH
(ADAQ) 2.438 INCHES NOMINAL
BODY WIDTH
(ADAT) 1.812 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) FULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING METHOD
(AXGY) THREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT
(CRBZ) 10.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 5TH SECONDARY
WINDING OPERATING CURRENT
(CRBZ) 110.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT
(CRBZ) 260.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT
(CRBZ) 850.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 104.00 AC VOLTS MINIMUM AND 126.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 11.50 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 17.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 17.50 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 35.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 66.00 DC VOLTS NOMINAL SINGLE COMPONENT 5TH SECONDARY
WINDING SHIELDING METHOD
(ACZX) INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY
(TTQY) 12 WIRE HOOK
THREAD SERIES DESIGNATOR
(THSD) UNC SINGLE GROUP
UNABLE TO DECODE
(AASA) UNABLE TO DECODE
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT

Manufacturer Part Numbers

204292

RNCC
5
RNVC
9
204292

RNCC
3
RNVC
2
B204292

RNCC
5
RNVC
9
BTC8300

RNCC
5
RNVC
9
TF4SX02EB

RNCC
C
RNVC
1

Related Inventory

12-04292
4010-5000
Condition NE
1/2 (.500) Exte
Readily Available
204292
5950002431466
Condition NS
TRANSFORMER
Readily Available
KBM3454
6105012042920
Condition NS
MOTOR
Readily Available
11204292
5305-01-120-4292
SCREW,CAP,HEXAG
Readily Available


 