NSN 5950-00-646-2470, 5950006462470
Cancelled -> Replaced by 5950003310587

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 006462470
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-646-2470
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-646-2470


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-646-2470

National Stock Number (NSN) 5950-00-646-2470, or NIIN 006462470, (transformer,power) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 2 stock numbers: 5950002553074, 5950003310587.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950006462470 does not contain precious metals.

This information was last updated on .


Technical Characteristics

FREQUENCY RATING
(ACZB) 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
UNABLE TO DECODE
(AAJD) UNABLE TO DECODE
BODY HEIGHT
(ADAU) 5.250 INCHES MINIMUM AND 5.438 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 4.531 INCHES MINIMUM AND 4.656 INCHES MAXIMUM
BODY WIDTH
(ADAT) 3.375 INCHES MINIMUM AND 3.500 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 3.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) HERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT
(ABKW) 6.375 INCHES MAXIMUM
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING METHOD
(AXGY) THREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE
(CQJX) 0.250 INCHES SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 1.2 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT
(CRBZ) 4.5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 6.40 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING SHIELDING METHOD
(ACZX) INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY
(TTQY) 12 STANDOFF, SOLDER LUG
THREAD QUANTITY PER INCH
(CMLP) 20 SINGLE GROUP
THREAD SERIES DESIGNATOR
(THSD) UNC SINGLE GROUP
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT