ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5985-00-161-7804, 5985001617804
LINE,RADIO FREQUENCY TRANSMISSIO

Federal Supply Classification
FSC 5985 - Antennas, Waveguides, and Related Equipment
National Item Identification Number
NIIN 001617804
Codification Country
United States
Item Name Code
INC 00884
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5985-00-161-7804
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5985-00-161-7804


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5985-00-161-7804

National Stock Number (NSN) 5985-00-161-7804, or NIIN 001617804, (line,radio frequency transmissio) was assigned November 3, 1971 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00884. [AN ITEM DESIGNED PRIMARILY FOR THE CONDUCTION OF RADIO FREQUENCY ENERGY, AND CONSISTING OF TWO OR MORE CONDUCTORS SUPPORTED IN FIXED SPATIAL RELATIONSHIP(S) ALONG THEIR OWN LENGTH. SINCE THE CHARACTERISTIC IMPEDANCE OF THE LINE IS DETERMINED BY THE SPATIAL RELATIONSHIPS OF THE CONDUCTORS, WHICH ARE SUFFICIENTLY RIGID TO MAINTAIN THESE RELATIONSHIPS BETWEEN SUPPORTS, THE CONFIGURATION OF THE ITEM IS USUALLY NOT SUSCEPTIBLE TO MECHANICAL MANIPULATION; THAT IS, IT IS NOT NORMALLY FLEXIBLE. INCLUDES A SINGLE CONDUCTOR INCLOSED IN AN OUTER CONCENTRIC CONDUCTOR (COAXIAL) OR TWO OR MORE CONDUCTORS LAID PARALLEL. ALL TYPES HAVE LOW LOSS OR SPECIAL CHARACTERISTICS AT HIGH FREQUENCIES. MAY INCLUDE FITTINGS OR TERMINATIONS. FOR ITEMS HAVING CONTINUOUS HOMOGENEOUS DIELECTRIC, SEE CABLE, RADIO FREQUENCY. SEE ALSO LINE SECTION, RADIO FREQUENCY TRANSMISSION.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5985001617804 contains silver.

This NSN is associated to Schedule B 8529109000: antenna & antenna reflectors of all kinds; parts suitable for use soley or principally w/ apparatus of heading 8525 to 8528, nesoi. The Schedule B End Use is listed as telecommunications equipment. NAICS classification category 334220: radio and television broadcasting and wireless communications equipment manufacturing.

This information was last updated on .


Technical Characteristics

III PRECIOUS MATERIAL AND LOCATION
(PMLC) CONTACT SURFACE SILVER
III FSC APPLICATION DATA
(ZZZV) RADAR SET,GUIDED MISSILE
ACCOMMODATED CONDUCTOR TYPE
(AQCE) COAXIAL
CAPACITANCE IN PICOFARADS PER UNIT LENGTH
(APZA) 29.3 PER FOOT
CHARACTERISTIC IMPEDANCE IN OHMS
(AJDD) 50.0
CONDUCTOR QUANTITY
(AMQN) 1
CONDUCTOR SIZE
(ACVL) 19 AWG
FSC APPLICATION DATA
(ZZZV) RADAR SET,GUIDED MISSILE
INSULATION SPACER OUTSIDE DIAMETER
(AQBA) 0.101 INCHES NOMINAL
INSULATION SPACER SHAPE
(APZD) TUBULAR
OUTSIDE DIAMETER
(ABHE) 0.141 INCHES NOMINAL
OVERALL LENGTH
(AAJU) 5.940 INCHES
MATERIAL
(MATT) COPPER ALLOY 102 OR COPPER ALLOY 120 OR COPPER ALLOY 122
PRECIOUS MATERIAL AND LOCATION
(PMLC) CONTACT SURFACE SILVER
PRECIOUS MATERIAL
(PRMT) SILVER
SURFACE TREATMENT
(SFTT) SILVER CONDUCTOR
TUBING OUTSIDE DIAMETER
(AQRX) 0.141 INCHES NOMINAL
TUBING INSIDE DIAMETER
(AQRY) 0.101 INCHES NOMINAL
UNABLE TO DECODE
(APZC) UNABLE TO DECODE
III PRECIOUS MATERIAL
(PRMT) SILVER
UNABLE TO DECODE
(AQBD) UNABLE TO DECODE
CONDUCTOR MATERIAL
(APYQ) COPPER, QQ-W-343, SOFT
OUTER CONDUCTOR
(APZC) INCLUDED
UNABLE TO DECODE
(AQAZ) UNABLE TO DECODE
INSULATION SPACER MATERIAL
(AQAZ) PLASTIC, MIL-P-19468
TERMINAL FITTING
(AQBD) INCLUDED
UNABLE TO DECODE
(AQRW) UNABLE TO DECODE
SURFACE TREATMENT
(SURF) TIN PLATED, MIL-T-10727
UNABLE TO DECODE
(APYQ) UNABLE TO DECODE
CONDUCTOR SURFACE TREATMENT
(AQRW) SILVER PLATED
MATERIAL
(MATL) COPPER, WW-T-799

Manufacturer Part Numbers


Related Inventory



 
Top