ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6130-01-524-0406, 6130015240406
POWER SUPPLY,UNINTERRUPTIBLE

Federal Supply Classification
FSC 6130 - Converters, Electrical, Nonrotating
National Item Identification Number
NIIN 015240406
Codification Country
United States
Item Name Code
INC 67374
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6130-01-524-0406
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6130-01-524-0406


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6130-01-524-0406

National Stock Number (NSN) 6130-01-524-0406, or NIIN 015240406, (power supply,uninterruptible) was assigned September 22, 2004 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 67374. [AN ITEM THAT PROVIDES CONTINUOUS BACKUP POWER TO ELECTRONIC DEVICES IN THE EVENT OF A UTILITY POWER DIP OR BLACKOUT. IT GENERALLY CONTAINS A BATTERY AND A POWER INVERTER THAT PROVIDES THE NECESSARY BACKUP POWER IN THE EVENT OF A LOSS OF NORMAL INPUT UTILITY POWER. IT MAY ALSO CONTAIN A POWER LINE FILTER OR POWER LINE CONDITIONING DEVICES. EXCLUDES:POWER SUPPLIES WITHOUT STANDBY POWER, ELECTRICAL POWER INVERERS, AND BATTERIES.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6130015240406 does not contain precious metals.

This information was last updated on .


Technical Characteristics

INPUT VOLTAGE RATING
(APNX) 240.0 AC POUNDS PER HOUR WET 5TH ALTERNATE OPERATING POWER RQMT
OPERATING AMBIENT TEMP RANGE
(AYNH) +50.0/+104.0 DEG FAHRENHEIT
III OUTPUT VOLTAGE RATING
(APPA) 230.0 AC VOLTS NOMINAL 1ST POWER OUTPUT
INPUT VOLTAGE RATING
(APNX) 208.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM 4TH ALTERNATE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT
BATTERY FEATURE AND TYPE
(CWHY) RECHARGEABLE LEAD ACID CELL
BATTERY POWER SUPPLY EMERGENCY OPERATING TIME
(CXMX) 15.0
BATTERY RECOVERY TIME
(CWWB) 120.0
FREQUENCY REGULATION PERCENT
(ANRQ) 0.5 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM 5TH ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 200.0 AC VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 208.0 AC VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 220.0 AC VOLTS NOMINAL 3RD ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 230.0 AC VOLTS NOMINAL 4TH ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 240.0 AC VOLTS NOMINAL 5TH ALTERNATE OPERATING POWER RQMT
OUTPUT CURRENT RATING
(CWGH) 26.0 AC AMPERES MAXIMUM 1ST POWER OUTPUT
OUTPUT CURRENT RATING
(CWGH) 29.0 AC AMPERES MAXIMUM 2ND POWER OUTPUT
OUTPUT CURRENT RATING
(CWGH) 30.0 AC AMPERES MAXIMUM 3RD POWER OUTPUT
OUTPUT FREQUENCY RATING
(APTS) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT WATTAGE RATING
(BGQR) 6000.0 WATTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT VOLTAGE RATING
(APPA) 200.0 AC VOLTS NOMINAL 3RD POWER OUTPUT
OUTPUT VOLTAGE RATING
(APPA) 208.0 AC VOLTS NOMINAL 2ND POWER OUTPUT
OUTPUT VOLTAGE RATING
(APPA) 230.0 AC VOLTS NOMINAL 1ST POWER OUTPUT
OVERALL HEIGHT
(ABKW) 10.500 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 24.750 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 17.250 INCHES NOMINAL
MAXIMUM OPERATING ALTITUDE RATING
(AKAE) 10000.0 FEET
OPERATING AMBIENT TEMP RANGE
(AYNH) +50.0 TO 104.0 FAHRENHEIT
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) R6000 EXTENDED RUNTIME MODULE
SPECIAL FEATURES
(FEAT) OVERALL LENGTH INCLUDING BEZEL 25.750 INCHES; INPUT VOLTAGE USER SELECTABLE; ELECTRICAL INPUT CONNECTION IS HARDWIRED; ELECTRICAL OUTPUT CONNECTIONS (3) IEC-320 16 AMP AND (12) IEC-320 10 AMP DIVIDED INTO 5 LOAD SEGMENTS; OUTPUT PROTECTION ONE 10 AMP RESETTABLE CIRCUIT BREAKER FOR EACH LOAD SEGMENT; 2 SERIAL COMMUNICATION PORTS FOR INTELLIGENT POWER MANAGEMENT SOFTWARE AND OPTION CARDS; USER LIGHT EMITTING DIODES(LED) GREEN-NORMAL OPERATION YELLOW-ON BATTERY YELLOW-ON BYPASS RED-ALARM; TWO-LINE LCD. WITH 3 BUTTON CONTROL; STORAGE TEMPERATURE 32.0 TO 77.0 DEGREES F; OPERATING HUMIDITY 20.0 TO 80.0 PERCENT NON-CONDENSING
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
OPERATING AMBIENT TEMP RANGE
(AYNH) +50.0 TO 104.0 DEG FAHRENHEIT
INPUT VOLTAGE RATING
(APNX) 200.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT
III OUTPUT VOLTAGE RATING
(APPA) 200.0 AC VOLTS NOMINAL 3RD POWER OUTPUT
III OUTPUT VOLTAGE RATING
(APPA) 208.0 AC VOLTS NOMINAL 2ND POWER OUTPUT
INPUT FREQUENCY RATING
(APTQ) 50.0 HERTZ MINIMUM 5TH ALTERNATE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM 5TH ALTERNATE OPERATING POWER RQMT
OUTPUT FREQUENCY RATING
(APTS) 50.0 HERTZ MINIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS AND 60.0 HERTZ MAXIMUM MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
INPUT VOLTAGE RATING
(APNX) 220.0 AC POUNDS PER HOUR WET 3RD ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 230.0 AC POUNDS PER HOUR WET 4TH ALTERNATE OPERATING POWER RQMT

Manufacturer Part Numbers


Related Inventory



 