NSN 6150-01-432-9018, 6150014329018
LOAD BANK,ELECTRICAL

Federal Supply Classification
FSC 6150 - Miscellaneous Electric Power and Distribution Equipment
National Item Identification Number
NIIN 014329018
Codification Country
United States
Item Name Code
INC 33776
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6150-01-432-9018
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6150-01-432-9018


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6150-01-432-9018

National Stock Number (NSN) 6150-01-432-9018, or NIIN 014329018, (load bank,electrical) was assigned June 17, 1996 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Sep 02, 2000, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 33776. [A_SET_(BANK)_OF_ELECTRICAL_ELEMENTS_THAT_ARE_PASSIVE_(RESISTIVE,_INDUCTIVE,_CAPACITIVE)_OR_ACTIVE_(MOTORS,_BATTERIES)._THEY_ARE_USUALLY_LOCATED_ADJACENT_TO_EACH_OTHER_TO_FORM_A_CONSOLIDATED_SET_OF_ANY_OF_THESE_ELEMENTS_OR_ANY_COMBINATION_OF_THEM._A_LOAD_BANK_IS_USED_TO_REPLACE_DISTRIBUTED_OR_DISPERSED_LOAD_ELEMENTS_CONTAINED_IN_A_POWER_DISTRIBUTION_SYSTEM_OR_ELECTRICAL_NETWORK_FOR_THE_PURPOSE_OF_PROVIDING_A_CONCENTRATED_LOAD._A_LOAD_BANK_CONTAINS_ALL_THE_ESSENTIAL_ELECTRICAL_CHARACTERISTICS_NECESSARY_TO_TERMINATE_THE_CIRCUIT_AND_FUNCTIONS_IN_THE_SAME_MANNER_AS_THE_LOAD_WHICH_IT_IS_INTENDED_TO_REPLACE._THIS_DESCRIPTION_NECESSARILY_INCLUDES_A_BANK_OF_LIGHT_BULBS_OR_CONE_HEATING_ELEMENTS_WHERE_ENERGY_CONVERSION_IS_PRIMARILY_IN_THE_FORM_OF_HEAT_ALTHOUGH_VISIBLE_RADIANT_ENERGY_IS_THE_NATURAL_RESULT_OF_INCANDESCENT_HEATING._LOAD_BANKS_ARE_INTENDED_TO_COVER_A_SPECIFIC_RANGE_OF_CHARACTERISTICS_AND_NORMALLY_OPERATE_AT_DC_OR_AT_POWER_FREQUENCIES_50,_60,_OR_400_HZ_AC._LOAD_BANKS_MAY_BE_UNINSTRUMENTED_OR_COMPLETE_WITH_INTEGRAL_INSTRUMENTION_AND_MAY_ALSO_BE_FURNISHED AS SKID OR TRAILER MOUNTED. EXCLUDES:TEST SET, ELECTRICAL (AS MODIFIED). SEE ALSO DUMMY LOAD, ELECTRICAL.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6150014329018 does not contain precious metals.

This NSN is associated to Schedule B 8543909000: electrical machines and apparatus parts, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335999: all other miscellaneous electrical equipment and component manufacturing.

This information was last updated on .


Technical Characteristics

ELECTRICAL POWER SOURCE RELATIONSHIP
(AKWC) OPERATING
ENCLOSURE FEATURE
(ANPZ) SINGLE ITEM W/HOUSING
AC VOLTAGE RATING
(ACYN) 115.0 VOLTS NOMINAL
DC VOLTAGE RATING
(ACYR) 1.5 VOLTS MINIMUM AND 500.0 VOLTS MAXIMUM
DEPTH
(AEJZ) 25.000 INCHES NOMINAL
END ITEM IDENTIFICATION
(AGAV) POWER SUPPLY TEST STATION NSN 6625013991759DQ
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL
HEIGHT
(HGTH) 10.500 INCHES NOMINAL
OPERATING TEST CAPABILITY
(AQXZ) MAX POWER 2500 WATTS, 1.5 TO 60VDC AT 0-40 AMPS; 3 TO 200VDC AT 0-120 AMPS; 10 TO 400VDC AT 0-240 AMPS; AND 15 TO 500VDC AT 0-40 AMPS; EIGHT CARD SLOTS
PHASE
(FAAZ) SINGLE
SPECIAL FEATURES
(FEAT) DWG TITLE: PROGRAMMABLE ELECTRONIC LOAD SUBSYSTEM
WIDTH
(ABGL) 16.880 INCHES NOMINAL
TEST TYPE FOR WHICH DESIGNED
(AQXY) PROGRAMMABLE CURRENT,VOLTAGE,RESISTANCE, AND POWER
INCLOSURE FEATURE
(ANPZ) SINGLE ITEM W/HOUSING