ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6525-01-705-6915, 6525017056915
COLLIMATOR,RADIOGRAPHIC AND FLUO

Federal Supply Classification
FSC 6525 - Imaging Equipment and Supplies: Medical, Dental, Veterinary
National Item Identification Number
NIIN 017056915
Codification Country
United States
Item Name Code
INC 22121
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6525-01-705-6915
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6525-01-705-6915


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6525-01-705-6915

National Stock Number (NSN) 6525-01-705-6915, or NIIN 017056915, (collimator,radiographic and fluo) was assigned October 5, 2022 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 4 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 22121. [AN ITEM DESIGNED TO ADJUST THE RADIATION FIELD IN A CONTINUOUSLY VARIABLE SQUARE OR RECTANGULAR PATTERN, WHICH WILL REDUCE THE SCATTERED RADIATION. IT IS USED WITH AN X-RAY APPARATUS, RADIOGRAPHIC AND FLUOROSCOPIC.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6525017056915 does not contain precious metals.

This NSN is associated to Schedule B 9022906000: parts and accessories of apparatus based on the use of x-rays. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 334517: irradiation apparatus manufacturing.

This information was last updated on .


Technical Characteristics

PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) COLLIMATOR,RADIOGRAPHIC AND FLUOROSCOPIC X-RAY APPARATUS
SPECIAL FEATURES
(FEAT) COLLIMATOR FOR USE WITH X-RAY APPARATUS,RADIOGRAPHIC SUITE,MEDICAL

Manufacturer Part Numbers


Related Inventory



 
Top