ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5910-01-140-9432, 5910011409432
CAPACITOR,FIXED,ELECTROLYTIC

Federal Supply Classification
FSC 5910 - Capacitors
National Item Identification Number
NIIN 011409432
Codification Country
United States
Item Name Code
INC 00008
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5910-01-140-9432
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5910-01-140-9432


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5910-01-140-9432

National Stock Number (NSN) 5910-01-140-9432, or NIIN 011409432, (capacitor,fixed,electrolytic) was assigned October 21, 1982 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00008. [A CAPACITOR, WHOSE CAPACITANCE VALUE CANNOT BE ADJUSTED OR VARIED, HAVING A CHEMICALLY FORMED FILM AS THE DIELECTRIC. IT MAY BE A SINGLE UNIT, OR CONSIST OF TWO OR MORE FIXED UNITS WHICH CANNOT BE SEPARATED.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5910011409432 does not contain precious metals.

This NSN is associated to Schedule B 8532290040: fixed capacitors, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

NONDERATED OPERATING TEMP
(CQJJ) -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED
TOLERANCE RANGE PER SECTION
(CRTP) -20.00/+20.00 PERCENT SINGLE SECTION
ELECTRICAL POLARIZATION
(AECQ) POLARIZED
ANODE TYPE
(AECE) SOLID
BODY DIAMETER
(ABPM) 0.421 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 0.828 INCHES MAXIMUM
BODY STYLE
(AAQL) W/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION
(CQBQ) 650.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIAL
(CWNJ) TANTALUM
CASE INSULATION MATERIAL
(CWSZ) PLASTIC
CASE MATERIAL
(CWJK) METAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP
(CQLH) 24.0 MICROAMPERES
DC LEAKAGE AT REFERENCE TEMP
(CWQH) 6.000 MICROAMPERES
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS
(CWQC) 1.80
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS
(AECN) 13.0
NONDERATED OPERATING TEMP
(CQJJ) -55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
(CQWM) 20.0 DC SINGLE SECTION
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATOR
(AEBZ) ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL DIAMETER
(AEBT) 0.025 INCHES NOMINAL
TERMINAL LENGTH
(ABJT) 2.000 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY
(TTQY) 2 UNINSULATED WIRE LEAD
TERMINAL SURFACE TREATMENT
(CWSG) SOLDER
TOLERANCE RANGE PER SECTION
(CRTP) -20.00 TO 20.00 PERCENT SINGLE SECTION
UNABLE TO DECODE
(ABKW) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 
Top